Datasheet

Removing a Mini-Physical Interface Module from the SRX Series Services Gateway on
page 20
SRX Series Services Gateway Mini-Physical Interface Modules Overview on page 4
Removing a Blank Mini-Physical Interface Module Faceplate from the SRX Series Services
Gateway
To maintain proper airflow through the services gateway, a blank faceplate should cover
any empty Mini-Physical Interface Module (Mini-PIM) slot.
CAUTION: Do not remove a blank faceplate unless you are installing a
Mini-PIM in the empty slot.
CAUTION: The Mini-PIMs available on the SRX Series Services Gateway are
not hot-swappable. You must power off the device before removing or
installing Mini-PIMs.
To remove a blank faceplate from the SRX Series Services Gateway:
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to the ESD point on the device.
2. If the device is powered on, power off the device. Verify that the Power LED is off.
3. Loosen the screws on each side of the faceplate.
On faceplates with handles, use a 1/8-in. (3-mm) flat-blade (–) screwdriver to
loosen but not remove the captive screws.
On faceplates without handles, use a number 1 Phillips screwdriver to remove the
noncaptive screws.
4. Remove the faceplate. See Figure 6 on page 18.
Figure 6: Removing a Blank Mini-PIM Faceplate from an SRX Series
Services Gateway
Copyright © 2012, Juniper Networks, Inc.18
SRX Series Services Gateways for the Branch Physical Interface Modules Hardware Guide