Services Routers Hardware Guide
CAUTION: Do not install a combination of modules in a single chassis that exceeds
the maximum power and heat capacity of the chassis. If J-series power management
is enabled, PIMs and modules (PIMs or PIMs plus a WXC Integrated Services Module)
that exceed the maximum power and heat capacity remain offline when the chassis
is powered on.
To verify that the combination of PIMs to be installed in a chassis does not exceed
the power and heat capacities for the J4350 or J6350 router, see “Planning for Power
Management” on page 72.
Table 20: J4350 and J6350 Field-Replaceable PIM and Module Summary
Sample Interface Name
(type-pim/0/port)Slot and Port Numbering
Supported Software Releases
for This PIMPIM
ge-2/0/0
Slots—1 through 6
Port—0
Release 8.5 and later of JUNOS
software with enhanced
services
1-Port SFP Gigabit
Ethernet uPIM
ge-2/0/5
Slots—1 through 6
Ports—0 through 5
Release 8.5 and later of JUNOS
software with enhanced
services
6-Port SFP Gigabit
Ethernet uPIM
ge-2/0/7
Slots—1 through 6
Ports—0 through 7
Release 8.5 and later of JUNOS
software with enhanced
services
8-Port Gigabit Ethernet
uPIM
ge-2/0/15
Slots—1 through 6
Ports—0 through 15
Release 8.5 and later of JUNOS
software with enhanced
services
16-Port Gigabit Ethernet
uPIM
ge-3/0/0
Can be installed in any
high-speed slot, as follows:
■
J4350: Slots 3 and 6
Port—0
■
J6350: Slots 2, 3, 5,
and 6
Port—0
Release 8.5 and later of JUNOS
software with enhanced
services
1-Port SFP Gigabit
Ethernet ePIM
se-3/0/1
Slots—1 through 6
Ports—0 and 1
Release 8.5 and later of JUNOS
software with enhanced
services
Dual-Port Serial PIM
t1-0/0/1
or
e1-0/0/1
Slots—1 through 6
Ports—0 and 1
Release 8.5 and later of JUNOS
software with enhanced
services
Dual-Port T1 or E1 PIM
ct1-0/0/0
ce1-0/0/0
Slots—1 through 6
Port—0 and 1
Release 8.5 and later of JUNOS
software with enhanced
services
Dual-Port Channelized
T1/E1/ISDN PRI PIM
40 ■ Field-Replaceable PIMs
JUNOS Software with Enhanced Services Hardware Guide