Network Scanner Operator's Guide
6.3 Network Connection Troubleshooting
Network Scanner fi-6000NS Operator's Guide 239
Troubleshooting
6
The following outcomes are possible:
Message
Connection
status
Action
System time has been
successfully synchronized.
OK None
System time synchronization
failed.
Sending resync command to
local computer...
The computer did not resync
because no time data was
available.
NG Try the following:
• Check the NTP server name and address settings
for errors.
• Check the network path between to the NTP
server for problems.
• The NTP server may be busy. Wait a short time
before trying again to synchronize the system
time. If that does not work, the specified server
may not be an NTP server, so try a different NTP
server.
• The specified NTP server cannot provide a
trusted date and time. It attempted to acquire the
date and time from a higher level NTP server,
but failed. Try a different NTP server or have the
network administrator investigate.
System time synchronization
failed.
Sending resync command to
local computer...
The computer did not resync
because only stale time data
was available.
System time synchronization
failed.
Sending resync command to
local computer...
The computer did not resync
because the required time
change was too big.
NG Refer to "3.5.4 Setting the Date/Time" (page 44),
adjust the date/time, and try again.