Table 38: EX Series Switch Environmental Tolerances (continued)
ToleranceDescription
Normal operation ensured in relative humidity range of 10% through
85%, noncondensing
Relative humidity
EX2200, EX3200, EX4200, and EX4500 switches: Normal
operation ensured in temperature range of 32° F through 113° F
(0° C through 45° C)
EX8208 and EX8216 switches: Normal operation ensured in
temperature range of 32° F through 104° F (0° C through 40° C)
Temperature
Complieswith Zone 4 earthquake requirements as per GR-63, Issue
3.
Seismic
NOTE: Install EX Series switches only in restricted areas, such as dedicated equipment
rooms and equipment closets, in accordance with Articles 110–16, 110–17, and 110–18
of the National Electrical Code, ANSI/NFPA 70.
Related Topics Clearance Requirements for Airflow and Hardware Maintenance for EX2200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX3200 and
EX4200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX4500 Switches
Clearance Requirements for Airflow and Hardware Maintenance for an EX8208 Switch
on page 101
Clearance Requirements for Airflow and Hardware Maintenance for an EX8216 Switch