Quick Start Guide

Campus Connectivity MP Quick Start Guide
10
Trapeze Networks
Installing an MP-632
The MP-632 includes a bracket kit for mounting the unit to a 3.81 to 5.08 cm (1.5 to 2-inch) diameter
steel pole or tube. The unit also has a wall-mounting bracket kit that can be used to install the unit on
a building wall. You also have the option to mount the MP on a larger pole (up to 30.48 cm or 12-inch
diameter) using the bracket kit and two metal band straps (straps not provided by Trapeze).
Hardware installation of the MP-632 involves these steps:
1. Mount the unit on a wall, pole, mast, or tower using the mounting bracket.
2. Mount external antennas on the same supporting structure as the MP-632 and connect them to
the unit.
3. Connect the Ethernet cable and a grounding wire to the unit.
4. Connect the other end of the circular DIN power cable to the XPS campus connectivity power
supply.
5. Connect the circular DIN Ethernet cable and prepare the RJ45 cable with the waterproof cap that
is provided. The waterproof caps must be installed on the RJ-45 cable in order to prevent water
damage.
W arning!
The MP-632 must only be used with a Trapeze-approved XPS-6201-OUT or
XPS-6202-OUT power supply in order to prevent possible damage to the unit.
Note:
Two separate cables are required for power and ethernet function on the MP-632.
Both the cable dongles are RJ-45 on one end, but one cable is specific to power and
one is specific to data. If the RJ-45 cable ends are swapped, the unit does not power
up but is not damaged. If the RJ-45 cable ends are correctly inserted, the unit
functions normally.
5GHz
Antenna Ports
Power
Ethernet Port