32
Trapeze Networks
4. Remove the bracket as shown in Figure 1–25.
Figure 1–25. Step 4—Removing the Bracket
5. As shown in Figure 1–26, feed the Cat 5 cable(s) through the port connector opening and align the
universal mounting bracket over the drywall anchors so that the two screw holes in the bracket
face the drywall anchors.
6. Insert the #6 sheet metal screws into the screw holes, and tighten them to secure the universal
mounting bracket to the wall or ceiling.
(If you routed the Cat 5 cable through a hole in the wall or ceiling, insert the screw into the center
screw hole only.)
Note:
Do not insert screws in the four holes on the edges of the bracket. (These are the holes
indicated by the dashed lines in Figure 1–26.) The MP fits into these holes. They are
not screw holes.