User's Manual

Indoor Mobility Point™ Quick Start Guide
18
Trapeze Networks
3. Unlock the MP by inserting the lock/unlock tool into the Unlock hole and push until you feel the
internal bracket slide across.
4. Mount the MP-82 onto the mounting bracket.
5. Lock the MP onto the bracket by inserting the lock/unlock tool into the Lock hole on the MP and
push until you feel the internal bracket slide across
Installing an Indoor MP-422/432/522
Suspended Ceiling Installation — Flush Ceiling Tiles for the MP-422/432/522
1. Select an installation location centered over a T-bar in the ceiling.
2. Cut a hole as follows in the ceiling tile for the Cat 5 cable(s):
a. Place the mounting template over the area where you plan to install the MP.
b. Use the box cutter to cut along the line marking the opening for the port connectors.
c. Remove the mounting template and the material you cut from the ceiling panel.
3. Determine whether to install a T-bar clamp onto the ceiling T-bar:
If the T-bar width is 14.2 millimeter (9/16 inches), you need to install the 14.2-millimeter (9/
16 inches) T-bar clamp. Go to step 4.
If the T-bar width is 23.9 millimeter (15/16 inches), the universal mounting bracket fits
directly onto the T-bar. Go to step 5.
4. Install the 14.2-millimeter (9/16-inch) T-bar clamp onto the ceiling T-bar as shown in Figure 1–5.
a. Slide each half of the clamp onto the T-bar so that the clamp lip is fully on the T-bar.
b. Slide the two halves of the clamp toward each other until the tabs are inserted completely into
the holes and the clamp fits snugly on the T-bar.
Figure 1–5. Step 4—Installing a T-bar Clamp
T-bar
T-bar clamp halves
Slide together