Cabling Requirements
Category 5 cable with straight-through signaling must be installed at the site before you install an
MP. A single connection requires one cable. A dual-homed connection requires two cables.
Mounting an MP on a solid surface requires Cat 5 cable that does not have strain relief. For
installation on all other surfaces, use a Cat 5 cable with or without strain relief.
Installing an Indoor Mobility Point
Installation Hardware and Tools
The table below lists the mounting hardware and tools required for each type of MP installation.
W arning!
Do not connect or disconnect cables or otherwise work with the MP hardware during
periods of lightning activity.
Note:
The MP is intended for indoor use only. Do not install the device outdoors, unless you
install it with a Trapeze Networks outdoor MP enclosure.
Note:
To reduce the possibility of connection interference caused by dust, clean the Cat 5
connector pins before inserting a cable into an MP.
Table 1– 2. Required Mounting Hardware and Tools
Mounting Option Required Hardware and Tools
Included with
the Product
Suspended ceiling—flush
ceiling tiles
Mounting template Yes
Universal mounting bracket Yes
T-bar clamp — A T-bar clamp is not required for a 23.9-millimeter
(15/16-inch) T-bar ceiling with flush ceiling tiles.
Yes
Box cutter No
Small screwdriver (3-millimeter or 1/8-inch) No
small-pointed instrument or a paperclip No