Indoor Mobility Point™ Quick Start Guide
38
Trapeze Networks
Installing an Indoor MP-522E
The MP-522E installation steps for ceiling or wall mount are the same as the MP-422/432/522 except
that you must install and orient the four antennas on the MP before supplying power to the unit. The
MP-522E has no internal antennas and requires antennas for all types of operation.Once the MP is
installed on either the wall or ceiling with antennas attached you can switch between Radio 1 and 2
using the CLI command “set ap # radio x mode disable.”
W arning!
Always install the four MP-522E antennas before supplying power to the MP. Failure to
do so can cause damage to the unit.
The tested/certified antennas are equipped with Reverse-SMA or N-type jacks.
This device and its antenna(s) must not be co-located or operated in conjunction with
any other antenna or transmitter.
The external connectors on the MP-522E are labeled 1, 2, 3, 6 on the housing. Each
connector is a RP-SMA connector. Make sure you attach the antenna to the correct
connector.
For products available in the USA/Canada market, only channel 1~11 can be operated.
Selection of other channels is not possible.
This device is going to be operated in 5.15~5.25GHz frequency range, it is restricted in
indoor environment only.