User's Manual
Installing and Connecting an Indoor MP
Installing an Indoor MP
Indoor Mobility Point Installation Guide
2 – 16
2. Install the drywall anchor(s):
a. Hammer a drywall anchor into each hole, up to the beginning of the threads on the anchor.
b. Screw each anchor the rest of the way into the hole using a #2 Phillips-head screwdriver.
c. Remove the screw from each anchor and save the screw(s) for step 6.
3. Unlock the universal mounting bracket from the MP by inserting a small-pointed instrument
or a paperclip into the Unlock hole on the MP as shown in
Figure 2–22.
Figure 2–22. Step 3—Unlocking the Bracket
4. Remove the bracket as shown in
Figure 2–23.
Figure 2–23. Step 4—Removing the Bracket
5. As shown in
Figure 2–24, feed the Cat 5 cable(s) through the port connector opening and align
the universal mounting bracket over the drywall anchors so that the two screw holes in the
bracket face the drywall anchors.
6. Insert the #6 sheet metal screws into the screw holes, and tighten them to secure the universal
mounting bracket to the wall or ceiling.
!
Caution
Use a small-pointed instrument or a paperclip to unlock the MP. Do not use a
screwdriver because it may cause damage to the MP lock mechanism or electronic
components. Do not use excessive force when inserting a tool into the Unlock or Lock
hole.