User's Manual

Installing and Connecting an Indoor MP
Installing an Indoor MP
Indoor Mobility Point Installation Guide
2 – 14
Figure 2–20. Step 3—Placing the Bracket on the Junction Box
4. Pull the Cat 5 cable(s) about 6 inches (about 15 cm) out of the junction box and through the
port connector opening to create enough slack to insert the cable(s) into the port connectors.
5. Insert the Cat 5 cable(s) into the connector(s):
For a single connection, use the connector for port 1.
For redundancy, insert one cable into each connector.
6. Install the Kensington lock, if you plan to use one.
a. Loop the Kensington lock cable around an object that cannot be moved or damaged by a
person pulling on the cable.
b. Insert the key into the Kensington lock.
c. Insert the Kensington lock into the security slot on the MP.
d. Rotate the key right or left to secure the lock to the MP.
e. Pull on the lock to verify that it is secured to the MP.
f. Remove the key.
7. Lift the MP into place on the universal mounting bracket.
Make sure the cable feeds properly into the junction box as you lift the device, and does not
become trapped between the MP and the bracket.
8. Lock the MP onto the bracket by inserting a small-pointed instrument or a paperclip into the
Lock hole on the MP as shown in
Figure 2–21.
Warning!
To prevent possible damage to the MP, make sure the device is fully locked onto the
bracket before releasing it.
Junction box
Port connector
opening