User's Manual

MP-622 Technical Specifications
Foreign Regulatory Requirements
MP-622 Technical Specifications 4 – 9
Safety Compliance
Power Cord Safety
Please read the following safety information carefully before installing the device:
The unit must be connected to an earthed (grounded) outlet to comply with international safety
standards.
Do not connect the unit to an A.C. outlet (power supply) without an earth (ground) connection.
The appliance coupler (the connector to the unit and not the wall plug) must have a
configuration for mating with an EN 60320/IEC 320 appliance inlet.
The socket outlet must be near to the unit and easily accessible. You can only remove power
from the unit by disconnecting the power cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950.
The conditions are only maintained if the equipment to which it is connected also operates under
SELV conditions.
Foreign Regulatory Requirements
France and Peru only
This unit cannot be powered from IT supplies. If your supplies are of IT type, this unit must be
powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection
point labelled Neutral, connected directly to earth (ground).
Impédance à la terre
Important! Before making connections, make sure you have the correct cord set. Check it (read
the label on the cable) against the following:
W arning!
Installation and removal of the unit must be carried out by qualified personnel only
Power Cord Set
USA and Canada
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
No. 18 AWG - not longer than 2 meters, or 16AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least 10A
The attachment plug must be an earth-grounding type with NEMA 5-15P (15 A, 125
V) configuration.
Denmark
The supply plug must comply with Section 107-2-D1, Standard DK2-1a or DK2-5a
Switzerland
The supply plug must comply with SEV/ASE 1011.
UK
The supply plug must comply with BS1363 (3-pin 13 A) and be fitted with a 5 A fused
which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75
(minimum).