54
Table 5. Health LED States
Health or LINK
LED Appearance
Diagnosis Remedy
Not solid green MP radio needs to be
enabled.
Enable at least one of the radios. If
the LED is still not solid green, try
the remedy listed in this table
based on the LED’s appearance.
Unlit MP access point is not
receiving power.
Check the Cat 5 cable
connection(s).
For a direct connection to an MX
switch:
• Set the port type on the MX
switch to an MP port.
• Verify that Power over Ethernet
(PoE) is enabled on the MX
switch port connected to the
MP access point.
For an indirect connection through
the network:
• Configure a Distributed MP
connection on an MX switch.
• Verify that a Trapeze-approved
PoE source is supplying power
to the MP.
Slowly alternating
green and amber
MP access point is booting
with an image received from
an MX switch.
Wait a few seconds for the boot
process to complete. If this LED
appearance persists, enable a radio
or place a radio in sentry mode.
Solid amber MP access point is waiting to
receive boot instructions and
a configuration file from an
MX switch.
Wait a few seconds for the boot
process to begin.
If the LED remains amber, try the
remedies for the other health LED
appearances.
If the LED still remains amber,
make sure the MP access point is
securely connected to its PoE
source and to the network or MX
switch.