User's Manual
Table Of Contents
- Customer Service
- Introducing the Trapeze Networks Mobility System
- MP Overview
- Installing and Connecting an MP
- MP Troubleshooting
- MP Technical Specifications
- Translated Warning Conventions and Warnings
- Index
Appendix A
Trapeze Mobility Point Installation Guide
Version 2.1
54
Confidential—Beta Draft—Confidential—Beta Draft—12 May 04
Table 6. Health LED States
Health LED
Appearance
Diagnosis Remedy
Not solid green MP radio needs to be
enabled.
Enable at least one of the radios. If
the LED is still not solid green, try
the remedy listed in this table
based on the LED’s appearance.
Unlit MP access point is not
receiving power.
Check the Cat 5 cable
connection(s).
For a direct connection to an MX
switch:
• Set the port type on the MX
switch to an MP port.
• Verify that Power over Ethernet
(PoE) is enabled on the MX
switch port connected to the
MP access point.
For an indirect connection through
the network:
• Configure a Distributed MP
connection on an MX switch.
• Verify that a Trapeze-approved
power injector is supplying
power to the MP.