Installing an MP—Model MP-241, MP-252, and MP-262
Chapter 3
Installing and Connecting an MP
29
Confidential—Beta Draft—Confidential—Beta Draft—12 May 04
Figure 14. Step 11—Locking the Bracket
12 To ensure that the MP access point is fully locked onto the bracket, gently pull
down on the access point and attempt to rotate it from side to side.
13 If the access point comes off the bracket, relock the device onto the bracket as
described in step 11 on page 28.
14 If the MP requires an external antenna, install and connect the antenna. (See
“Connecting an MP to an External Antenna” on page 47.)
15 If the other ends of the Cat 5 cable(s) are not already connected to an MX
switch and the link activated, go to “Connecting an MP to an MX Switch” on
page 48. Otherwise, go to “Verifying MP Health” on page 51.
Suspended Ceiling Installation—Drop Ceiling Tiles
(For required mounting hardware and tools, see Table 5 on page 22.)
1 Select an installation location that is centered over a T-bar in the ceiling.
2 Cut a hole as follows in the ceiling tile for the Cat 5 cable(s):
a Place the mounting template over the area where you plan to install the
MP access point.
b Use the box cutter to cut along the line marking the opening for the port
connectors.
840-9502-0006
L
o
ck
T-bar