Instruction Manual
Table Of Contents
■ Pull the control knob off the central plate so that the adjustment rings are vis-
ible Bild.
Pulling off is done by hand or with a suitable tool, e.g. vacuum lifting tool or
key cap puller.
■ Turn the large blue adjustment ring clockwise to the desired minimum temper-
ature. Each notch corresponds to a change of about 2°C.
■ Turn the small red adjustment ring anticlockwise to the desired maximum tem-
perature.
The respective adjustment ring can only be turned in one direction. To return
to the original setting, continue turning to the respective position.
■ Replace the control knob, observing the coding (Fig. 4, bottom) of the control
knob and rotary axle.
8 Technical data
Rated voltage AC 220 ... 240 V ~
Mains frequency 50 / 60 Hz
Switching current 10 A
Connected load
Ohmic load 2300 W
Standby power max. 0.15 W
Ambient temperature -5 ... +45 °C
Storage/transport temperature -25 ... +70 °C
Cable length inputs max. 100 m
Controller class (EU 811/2013) IV
Contribution to energy efficiency 2%
FFNTC remote sensor
Dimensions Ø×H 7.8 × 28 mm
Length connecting cable 4 m (can be extended to 50 m)
Degree of protection IP 67
Remote sensor resistance values
Temperature
(°C)
Resistance
(kΩ)
Temperature
(°C)
Resistance
(kΩ)
5 89.5 30 26.2
10 68.8 35 20.9
15 53.5 40 16.7
20 41.9 45 13.5
25 33.0 50 11.0
Floor thermostat
9 / 10
82404923 29.11.2022