Instruction Manual
Table Of Contents
6 Operation
Brief overview
Function Control knob Status LED * LED colour
Change room tem-
perature
... turn right or
left
maximum 2
minutes
Red = heating mode
green = ECO heating mode
Orange = frost protection (10
seconds)
Display operating
mode
... press briefly 10 seconds. Red = heating mode
green = ECO heating mode
Orange = frost protection
* In permanent operation, the status LED lights up continuously during the active
heating phase, but with reduced brightness.
Increasing or reducing the floor temperature
■ Turn the control knob to the right or left.
If the setpoint temperature is not reached, the LED lights up for a maximum of
2 minutes in the colour of the current operating mode. The indication can also
take place during the entire heating process (see Activating/deactivating per-
manent LED operation).
In the middle position, the device regulates to approx. 30 °C target temperat-
ure. The lowest target temperature is approx. 5 °C and the highest target tem-
perature is approx. 50 °C
Indication of the current operating mode
■ Press the control knob briefly.
The LED lights up for 10 seconds in the colour of the current operating mode.
Orange
= frost protection,
red
= heating mode,
green
= ECO heating mode.
Switching off the temperature control
■ Press the control knob for longer than 2 seconds until the LED lights up
or-
ange
.
The device has switched to frost protection. The frost protection prevents the
temperature from falling below 5 °C.
Each time the control knob is turned, the LED lights up
orange
for 10 seconds.
■ To activate the temperature control, press the control knob again for more
than two seconds.
The device switches back to heating mode. The LED lights up red for
10 seconds.
Floor thermostat
5 / 10
82404923 29.11.2022
J0082404923