Instruction Manual

24
Technical specifications
Motor size Motor 2 x OF302
Voltage Volt 100 100 120 200 200 230 230 3x400* 3x400*
Frequency Hz 50 60 60 50 60 50 60 50 60
Power HP 1,20 1,20 1,20 1,20 1,20 1,20 1,20 1,20 1,20
kW 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88
Displacement l/min 216 276 276 216 276 216 276 216 276
CFM 7,63 9,75 9,75 7,63 9,75 7,63 9,75 7,63 9,75
FAD @ 8 Bar *** l/min 76 88 88 76 88 76 88 76 88
CFM 2,68 3,11 3,11 2,68 3,11 2,68 3,11 2,68 3,11
Max. pressure** Bar 8 8 8 8 8 8 8 8 8
PSI 120 120 120 120 120 120 120 120 120
Max. current Amps 15,0 17,4 13,2 8,2 9,2 6,8 7,6 2,8 2,8
Noise level @ 1 m dB(a) 68 69 69 68 69 68 69 68 69
* Neutral is required.
** Available for operation at a higher pressure upon request.
Please note that operation at higher pressure will influence the life time.
*** Displacement is reduced by approx. 18-20% on units with dryer (D). Min. pressure required to operate dryer: 6 bar
Technical modifications reserved
Motor size Motor 3 x OF302
Voltage
Volt 100 100 120 200 200 230 230 3x400* 3x400*
Frequency
Hz 50 60 60 50 60 50 60 50 60
Power
HP 1,80 1,80 1,80 1,80 1,80 1,80 1,80 1,80 1,80
kW 1,32 1,32 1,32 1,32 1,32 1,32 1,32 1,32 1,32
Displacement
l/min 324 414 414 324 414 324 414 324 414
CFM 11,43 14,61 14,61 11,43 14,61 11,43 14,61 11,43 14,61
FAD @ 8 Bar ***
l/min 114 132 131 114 132 114 132 114 132
CFM 4,02 4,65 4,65 4,02 4,65 4,02 4,65 4,02 4,65
Max. pressure**
Bar 8 8 8 8 8 8 8 8 8
PSI 120 120 120 120 120 120 120 120 120
Max. current
Amps 22,5 26,1 19,8 12,3 13,8 10,2 11,4 4,2 4,2
Noise level @ 1 m
dB(a) 71 72 72 71 72 71 72 71 72