Owner manual

23
Technical specifications
Model Motor OF1201
Voltage Volt 100 100 120 200 200 208 230 230
Frequency Hz 50 60 60 50 60 60 50 60
Power HP 1,22 1,22 1,22 1,22 1,22 1,22 1,22 1,22
kW 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90
Displacement l/min 146 170 170 146 170 170 146 170
CFM 5,16 6,00 6,00 5,16 6,00 6,00 5,16 6,00
FAD @ 8 Bar ***
l/min 65 75 75 65 75 75 65 75
CFM 2,30 2,65 2,65 2,30 2,65 2,65 2,30 2,65
Max. pressure** Bar 8 8 8 8 8 8 8 8
PSI 120 120 120 120 120 120 120 120
Max. current Amps 13 13 11 6,5 6,5 6,5 6,2 5,8
Weight Kg 23 23 23 23 23 23 23 23
Lbs 51 51 51 51 51 51 51 51
Dimensions (l x w x h) mm 351 x 180 x 326
Inch 13.8 x 7.1 x 12.8
Noise level @ 1 m dB(a) 77 80 80 77 80 80 77 80
Technical specifications
* Neutral is required.
** Available for operation at a maximum pressure of 10 barg / 145 psig upon request.
Please note that operation at higher pressure will influence the life time.
*** Displacement is reduced by approx. 18-20% on units with dryer (D).
Min. pressure required to operate dryer: 6 barg
Technical modifications reserved
Model OF1201-25M OF1201-25MD2
Tank size liter 25 25
US gallon 6,6 6,6
Weight kg 88 98
lbs 194 216
Dimensions (l x w x h) mm 720 x 460 x 860
Inch 28.0 x 18.0 x 34.0
Pumping time
(0-8 bar/0-120 psi)
@ 50 Hz sec. 150 190
@ 60 Hz
sec. 110 160
Noise level @ 1 m @ 50 Hz dB(a) 58 58
@ 60 Hz
dB(a) 61 61