Digital input
Relay outputs
Measuring circuit monitoring
Voltage supply
Test voltages according to EN 60730, Part 1
Electrical safety
Connection Function
1 potential-free contact Unlocking, keyboard lock, level inhibit can be configured
Relay output KV Relay (changeover contact) without contact protection
30000 switching operations at a switching capacity of AC 250 V, 3 A, 50 Hz (resistive load)
or maximum DC 30 V, 3 A. Minimum current: DC 12 V, 100 mA
Alarm relay output Relay (changeover contact)
Contact protection circuit:
fuse cut-out 3.15 AT, installed in the N/O contact arm
30000 switching operations at a switching capacity of AC 230 V, 3 A, 50 Hz (resistive load)
or up to DC 30 V, 3 A. Minimum current: DC 12 V, 100 mA.
RTD temperature probe in three-
wire circuit and double thermocou-
ples
Thermocouples Current 4 to 20 mA
Out of range Is detected
LED K1, K2, KD, and KV are lit;
">>>>" flashes in the display for overrange, "<<<<" for underrange.
Probe/cable break Is detected
LED K1, K2, KD, and KV are lit;
">>>>" flashes in the display; alarm relay output is inactive
LED K1, K2, KD, and KV are lit;
">>>>" flashes in the display;
alarm relay output is inactive
Probe short circuit Is detected
LED K1, K2, KD, and KV are lit
"<<<<" flashes in the display;
alarm relay output is inactive
Is detected by difference monitor-
ing of the analog inputs
LED K1, K2, KD, and KV are lit;
"<<<<" flashes in the display;
alarm relay output is inactive
Voltage supply AC/DC 20 to 30 V, 48 to 63 Hz AC 110 to 240V, +10/-15 %, 48 to
63 Hz
Power consumption, power loss Max. 12 W Max. 12 W
Power consumption, power loss:
For the following operating mode
Analog output 10 mA; display backlight off; alarm relay output
switched on; pre-alarm relay switched off; sensor: 2xPt100
5 W 5 W
Input and output against voltage supply
- With a voltage supply of AC 110 to 240 V +10 % /-15 % 3.7 kV/50 Hz
- With a voltage supply of AC/DC 20 to 30 V, 48 to 63 Hz 3.7 kV/50 Hz
Clearances / creepage distances
Mains voltage to electronic compo-
nents and probes
6mm / ≥ 8mm
Mains voltage to relays
6 mm / ≥ 8 mm
Relays to electronic components and
probes
6 mm / ≥ 8 mm
Electrical safety According to DIN EN 14597 (DIN EN 60730-2-9)
Overvoltage category III, pollution degree 2
Protection rating I With internal isolation from SELV electrical circuits