ATEX identification marking, ignition protection type "e" and "t"
1-sensor-variant:
Standard designation according to EN 60079 for electrical devices
ignition protection „e“ increased safety according to EN 60079-7
ignition protection “t” dust explosion protection with housing accord. to EN 60079-31
D: dust explosion protection
Equipment Protection Level:
Gb: for use in zone 1 or 2 for gases
Db: for use in zone 21 or 22 for dust
II (2) G (b1) [Ex eb Gb] [Ex eb Gb] IIC(
II (2) D (b1) [Ex tb Db] [Ex tb Db] IIIC
Standard designation
Category according to ATEX directive 2014/34/EU
G: gas explosion protection
Guidelines designation for device group II (non-firedamp endangered mine workings)
Designation explosionproof according to ATEX directive 2014/34/EU
Standard designation according to EN 13463 for non electrical devices
„b1“ ignition source monitoring according to EN 13463-6 with IPL 1 (Ignition Prevention Level)
for category 2
Type: 701155/...-045 [Ex „e“, „t“]
Standard designation according to EN 50495
eb: increased safety b = zone 1 or 2 for gas
tb: protection with housing b = zone 21 or 22 for dust
Standard designation according to EN 60079-0
Explosion group II C gases, low ignition energy such as hydrogen
III C conductive dusts
Safety devices according to EN 50495 for category 2 applications for
ignition protection type increased safety "e" according to EN 60079-7
Safety device according to EN 13463-6 for category 2 applications for ignition protection:
Ignition source monitoring of non-electrical ignition dangers "b1" according to EN 13463-6
2-sensor-variant:
Type: 701155/...-045 [Ex „e“, „t“]
II (2) G (b2) [Ex eb Gb] [Ex eb Gb] IIC(
II (2) D (b2) [Ex tb Db] [Ex tb Db] IIIC
Standard designation according to EN 50495
eb: increased safety b = zone 1 or 2 for gas
tb: protection with housing b = zone 21 or 22 for dust
Standard designation according to EN 60079-0
Explosion group II C gases, low ignition energy such as hydrogen
III C conductive dusts
Standard designation according to EN 60079 for electrical devices
ignition protection „e“ increased safety according to EN 60079-7
ignition protection “t” dust explosion protection with housing accord. to EN 60079-31
Equipment Protection Level:
Gb: for use in zone 1 or 2 for gases
Db: for use in zone 21 or 22 for dust
Standard designation according to EN 13463 for non electrical devices
„b2“ ignition source monitoring according to EN 13463-6 with IPL 2 (Ignition Prevention Level)
for category 1
D: dust explosion protection
Category according to ATEX directive 2014/34/EU
G: gas explosion protection
Safety devices according to EN 50495 for category 2 applications for
ignition protection type increased safety "e" according to EN 60079-7
Safety device according to EN 13463-6 for category 2 applications for ignition protection:
Ignition source monitoring of non-electrical ignition dangers "b1" according to EN 13463-6
Guidelines designation for device group II (non-firedamp endangered mine workings)
Designation explosionproof according to ATEX directive 2014/34/EU
Standard designation