Technical data
Table of control ranges and probes for TR, TW, TB – gas-filled
Control ranges and temperature probes for STB and STW (STB) – liquid-filled
Control ranges and temperature probes for STB and STW (STB) – gas-filled
When the switching points are permanently factory-set, the deactivation value must be specified in addition to the control range
(e.g. control range 80 to 100 °C, permanently set to 95 °C).
Capillary and temperature probes
Note:
Upon request the capillary length can be increased up to a maximum of 5,000 mm if the allowable temperature on the sensor, capillary, and
switching head is not reached.
Please let us know the actual temperature values to which the thermostat is exposed.
Control range/
limit value range
°C
Switching
differential
%
Max.
probe
temperature
°C
Max.
switching head
temperature
°C
Max.
capillary length
in mm
Max.
sequence
contact gap
°C
Probe length "L" in mm,
probe Ø "d" in mm,
Ø "6" = Standard
Ø 6 Ø 8
20 to 400 06
10
+460
+500
+80 5000
075
200
237
127
137
081
20 to 500 3/5
06
10
+575 +80
1000
5000
5000
048
095
250
278
176
095
158
106
065
Setting range
°C
Scale range
°
Max.
probe
temperature
°C
Max.
switching head
temperature
°C
Max.
capillary length
in mm
Limit value
tolerance
°C
Probe length "L" in mm,
probe Ø "d" in mm,
Ø "6" = Standard
Ø 6 Ø 8
75 to 100 78 +125
+80 5000
+0
-7
84 63
85 to 110 78 +135
+0
-7
120 to 150 77 +173
+0
-9
80 57
160 to 200 79 +230
+0
-12
64 49
210 to 250 71 +288
+0
-13
61 47
250 to 300 79 +345
+0
-16
55
Setting range
°C
Scale range
°
Max.
probe
temperature
°C
Max.
switching head
temperature
°C
Max.
capillary length
in mm
Limit value
tolerance
°C
Probe length "L" in mm,
probe Ø "d" in mm,
Ø "6" = Standard
Ø 6 Ø 8
300 to 400 70 +460
+80 3000
+0
-23
148 92
350 to 500 72 +575
+0
-29
127 81
Type Scale limit value Capillary Temperature probe Notes
EM- . . Up to 200 °C Copper (Cu)
Ø 1.5 mm
Material no. Cu-DHP
Copper (Cu)
Material no. Cu-DHP
Hard soldered
Up to 350 °C Copper (Cu)
Ø 1.5 mm
Material no. Cu-DHP
Stainless steel (CrNi)
Material no. 1.4571
Hard soldered
Up to 500 °C Stainless steel (CrNi)
Ø 1.5 mm
Stainless steel (CrNi)
Material no. 1.4571
Welded
Up to 350 °C Stainless steel (CrNi)
Ø 1.5 mm
Stainless steel (CrNi)
Material no. 1.4571
Welded
Available at
extra cost
Capillary length Standard: 1000 mm, max. 5000 mm
Min. bending
radius
of capillary
5mm