Datasheet

2010-01-07/00415410
Data sheet 60.2031 Page 8/10
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone: +49 661 6003-0
Fax: +49 661 6003-607
E-mail: mail@jumo.net
Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow - Essex CM20 2DY, UK
Phone: +44 1279 63 55 33
Fax: +44 1279 63 52 62
E-mail: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone: 315-697-JUMO
1-800-554-JUMO
Fax: 315-697-5867
E-mail: info@jumo.us
Internet: www.jumo.us
Order details
Built-in thermostat JUMO heatTHERM type 602030 and 602031
Order code ( 1 ) Basic type
602030 Built-in thermostat JUMO heatTHERM with single-pole snap switch (TR/TW)
602031 Built-in thermostat JUMO heatTHERM with single-pole snap switch (STW/STB)
( 2 ) Basic type extensions
X 01 Temperature controller (TR) with change-over contact
X 02 Temperature monitor (TW) with change-over contact
X 20 Safety temperature monitor (STW) Set permanently with change-over contact
X 21 Safety temperature monitor (STW) Adjustable with change-over contact
X 80 Safety temperature limiter (STB) Set permanently with change-over contact
and restart lock
X 81 Safety temperature limiter (STB) Adjustable with change-over contact
and restart lock
( 3 ) Control / limit value range °C max. admissible probe temperature °C
X X 000 with permanently set switching point
X 026 0...+120 145
X 028 0...+200 230
X 041 +20...+90 115
X 064 +50...+300
(temperature probe made of CrNi)
345
X 043 +20...+150 180 ( at extra codes 749)
X 640 +50...+300
(temperature probe made of CrNi) 345 ( at extra codes 749)
X 666 +95...+120 145
X 671 +70...+130 155
further control/limit value ranges up to 350°C on request (up to +500°C without approval)
( 4 ) Limit value STW/STB permanently set
°C
max. admissible probe
temperature °C
Switching point tolerance
X 000 with adjustable limit value
X 095 +95 145 +0/-5K
X 100 +100 145 +0/-5K
X 110 +110 145 +0/-5K
further limit values up to 350°C on request (up to +500°C without approval)
( 5 ) Hysteresis %
X 00 no specifications for STB
X25 2.5
XX70 7
( 6 ) Long-distance line length mm
X X 2000 2000
X X .... Special length (specifications in plain text - 1000 mm steps, maximum length 5000 mm)
( 7 ) Long-distance line material
X X 40 Cu (copper) Ø 1.25 mm
( 8 ) Long-distance line insulation
XX13 With