Admissible load at the thermowell
Thermowells 820, 876, 871, 913
The following values describe the maximum capacity of the corresponding connection type.
The maximum sealable pressure depends on the fitting conditions and may be lower.
Thermowell made of stainless steel
Thermowell made of brass
Material Pipe and nipple: Stainless steel (1.4571)
Capacity Temperature Pipe diameter
8 x 0.75 mm or conical 10 x 0.75 mm
Max. allowable pressure
100 °C 92 bar 74 bar
150 °C 88 bar 71 bar
200 °C 83 bar 67 bar
300 °C 72 bar 58 bar
400 °C 67 bar 54 bar
Max. allowable
operating
temperature*
Static load +400 °C Without load +530 °C
Observe max. allowable probe temperature of the respective thermometer version.
Material Pipe and nipple: CuZn
Capacity Temperature Pipe diameter
8 x 0.75 mm 10 x 0.75 mm
Max. allowable pressure
100 °C 50 bar 40 bar
150 °C 48 bar 39 bar
Max. allowable
operating
temperature*
+150 °C