40100200T10Z001K000
Environmental influences
Medium temperature
for electrical connection
Attached cable -20 to +125 °C
Round plug M12 × 1 -20 to +125 °C
Bayonet connector -20 to +125 °C
Cable socket -20 to +125 °C
Ambient temperature
for electrical connection
Attached cable -20 to +100 °C
At ambient temperature of -30 °C restricted function. Only use when stationary.
Risk of cable break.
Round plug M12 × 1 -20 to +100 °C
Bayonet connector -20 to +100 °C
Cable socket -20 to +100 °C
Storage temperature
for electrical connection
Attached cable -30 to +100 °C
Round plug M12 × 1 -40 to +100 °C
Bayonet connector -40 to +100 °C
Cable socket -40 to +100 °C
Admissible humidity
Operation 100 % rel. humidity including condensation on the device outer case
Storage 90 % rel. humidity without condensation
Admissible mechanical load
Vibration resistance 50 g for 10 to 2000 Hz, according to IEC 60068-2-6
Shock resistance 50 g for 3 ms, 100 g for 2 ms, according to IEC 60068-2-27
Electromagnetic compatibility according to EN 61326-2-3
Interference emission Class B
a
Interference immunity Industrial requirement
Protection type
for electrical connection
according to EN 60529
Attached cable IP67
QUICKON
b
IP67
Round plug M12 × 1
c
IP67
Bayonet connector
c
IP67
Cable socket
c, d
IP65
a
The product is suitable for industrial use as well as for households and small businesses.
b
Connecting cable diameter, minimum 3.5 mm, maximum 6 mm
c
The protection type is only achieved with a suitable mounted counter piece.
d
Connecting cable diameter, minimum 6 mm, maximum 8 mm