Technical data
Inputs (main board)
Resistance thermometer inputs (optional board)
Standard signals inputs (optional board)
Main input Measuring range/control range Accuracy Effect of temperature
µS/cm 0.000 to 9.999
00.00 to 99.99
000.0 to 999.9
0000 to 9999
0.6 % of range + 0.3 µS × cell
constant (K)
0.2%/10K
mS/cm 0.000 to 9.999
00.00 to 99.99
000.0 to 999.9
0000 to 9999
a
a
In the range between 1 to 10 S the accuracy is 1 % of the measuring range.
0.6 % of range + 0.3 µS × cell
constant (K)
0.2%/10K
kΩ × cm 0.000 to 9.999
00.00 to 99.99
000.0 to 999.9
0000 to 9999
0.6 % of range + 0.3 µS × cell
constant (K)
0.2%/10K
MΩ × cm 0.000 to 9.999
00.00 to 99.99
000.0 to 999.9
0000 to 9999
0.6 % of range + 0.3 µS × cell
constant (K)
0.2%/10K
Secondary input
Temperature Pt100/1000 -50 to +250 °C
b
b
Selectable in °F
0.25 % of range 0.2 %/10 K
Temperature NTC/PTC 0.1 to 30 kΩ
Entry via table with 20 value pairs
1.5 % of range 0.2 %/10 K
Standard signal 0(4) to 20 mA or 0 to 10 V 0.25% of range 0.2 %/10 K
Resistance transmitter Minimum: 100 Ω
Maximum: 3 kΩ
±5 Ω 0.1%/10K
Designation Connection type Measuring range Measuring accuracy Effect of ambient
temperature
3-wire/4-wire 2-wire
Pt100 DIN EN 60751
(factory-set)
2-wire/3-wire/
4-wire
-200 to +850 °C 0.05 % 0.4 % 50 ppm/K
Pt1000 DIN EN 60751
(factory-set)
2-wire/3-wire/
4-wire
-200 to +850 °C 0.1 % 0.2 % 50 ppm/K
Sensor lead resistance Maximum 30 Ω per line with 3- and 4-wire circuit
Measurement current Approx. 250 µA
Lead compensation Not required for 3- and 4-wire circuit. With a 2-wire circuit, lead resistance can be compensated
in the software by correcting the process value.
Designation Measuring range Measuring accuracy Effect of ambient temperature
Voltage 0(2) to 10 V
0to1V
Input resistance
E
> 100 kΩ
0.05 % 100 ppm/K
Electrical current 0(4) to 20 mA,
voltage drop 1.5 V
0.05 % 100 ppm/K
Resistance transmitter Minimum: 100 Ω
Maximum: 4 kΩ
±4 Ω 100 ppm/K