Binary input
Relay outputs
Measuring circuit monitoring
Voltage supply
Test voltages as per EN 60730, part 1
Electrical safety
Connections Function
1 potential-free contact Unlocking, keyboard locking, level locking can be configured
Relay output KV Relay (change-over contact) without shroud
30,000 operations at a performance of 3 A /250 V, 50 Hz resistive load
Relay output alarm Change-over contact
Contact protection switching: safety fuse 3.15AT, installed in the NO contact arm
30,000 operations at a performance of 3 A /230 V, 50 Hz resistive load
RTD temperature probe in 3-wire
circuit and
double thermocouples
Thermocouples Current 4 to 20mA
Overrange
and underrange
is detected
LED K1, K2, KD and KV are lit;
">>>>“ flashes in the display for overrange, "<<<<“ for underrange.
Probe and wire break is detected
LED K1, K2, KD and KV are lit;
">>>>“ flashes in the display; relay output alarm is inactive
LED K1, K2, KD and KV are lit;
">>>>“ flashes in the display;
relay output alarm is inactive
Probe short-circuit is detected
LED K1, K2, KD and KV are lit;
"<<<<“ flashes in the display;
relay output alarm is inactive
is detected by difference moni-
toring of the analog inputs
LED K1, K2, KD and KV are lit;
"<<<<“ flashes in the display;
relay output alarm is inactive
Voltage supply AC/DC 20 to 30V, 48 to 63 Hz,
AC 110 to 240V +10% /-15%, 48 to 63Hz
Power consumption < 12 VA
Input and output against voltage supply
- at a voltage supply AC 110 to 240V +10% /-15% 3.7kV/50 Hz
- at a voltage supply AC/DC 20 to 30 V, 48 to 63 Hz 3.7kV/50 Hz
Clearances / creep paths
Mains to electronic components and
probes
6 mm8 mm
Mains to relays
6 mm8 mm
Relays to electronic components
and probes
6 mm8 mm
Electrical safety as per DIN EN 14597 (DIN EN 60730-2-9)
Overvoltage category III, pollution degree 2
Protection rating I with internal separation from SELV current circuits