Technical data
Technical data (general)
Input
Environmental influences
Electrical connection Machine connector M12 × 1, 4-pin according to IEC 60947-5-2
Process connections Screw connection G 3/8
Screw connection G 1/2
Screw connection G 1/2 with CIP-compliant conical seal
Taper socket with union nut (dairy compression fitting)
Clamping socket (clamp) DIN 32676
Ball welding socket with threaded fitting
Welding socket with CIP-compliant conical seal
VARIVENT®
a
connections
a
VARIVENT® is a registered trademark of GEA Tuchenhagen.
Ball welding sleeve
JUMO PEKA hygienic process connection
Protection tubes Stainless steel 316 L material-no. 1.4404/1.4435
Stainless steel 316 Ti material-no. 1.4571 (upon request)
Protection type IP67 according to DIN EN 60529 with inserted machine connector
Response times Standard protection tube t
0.5
= 5 s; t
0.9
= 12 s; in water 0.4 m/s
Stepped down protection tube t
0.5
= 2 s; t
0.9
= 5 s; in water 0.4 m/s
Standard protection tube t
0.5
= 40 s; t
0.9
= 110 s; in air 3.0 m/s
Stepped down protection tube t
0.5
= 21 s; t
0.9
= 70 s; in air 3.0 m/s
Measuring input
Without transmitter Pt100 or Pt1000 temperature sensor, DIN EN 60751, class A, B, and/or AA,
two or four-wire circuit
With programmable transmitter Pt1000 temperature sensor, DIN EN 60751, class A, four-wire circuit
Measuring ranges
Basic type 902815/10 and 902815/40 -50 to +200 °C
Basic type 902815/20 -50 to +150 °C
Basic type 902815/21 and 902815/41 -50 to +260 °C with extension tube
Limit deviations in °C Class A (standard): ±(0.15 + 0.002 × |t|) °C
a
a
|t| = temperature in °C regardless of the prefix.
Class AA: ±(0.10 + 0.0017 × |t|) °C
a
Class B: ±(0.30 + 0.005 × |t|) °C
a
Ambient temperature range of the head
Basic type 902815/10 and 902815/40 -30 to +90 °C
Basic type 902815/20, 902815/21, and
902815/41
-30to+85°C
Storage temperature range -30 to +90 °C
Resistance to climatic conditions According to IEC 60068-2-30 (relative humidity ≤ 95 % with condensation)
Vibration resistance According to IEC 60068-2-6 (according to GL characteristic line)