User Instructions

26
Unit does not respond to
activation
Unit responds slowly to
activation
Unit does not open fully
Mounting plate has been instal-
led too far back
Blum distance bumper pad not
inserted or positioned incorrectly
Front gap too small
Front gap too large
Trigger fails to initiate move-
ment across entire front height
Incorrect drilling cover (blocked
rod)
Refrigerator assembly stops
have not been removed
The reference run has not been
carried out correctly (e.g. due to
manual interference during the
reference run).
Check position using as-
sembly template
Ensure dimensions corre-
spond to
assembly instructions
Install Blum distance
bumper pad
Correct positioning
Adjust front gap to 2.53
mm (in accordance with
instructions for white goods)
Wireless switches are
recommended
Drill a new front
Remove in accordance with
white goods instructions
Reset system, begin a new
reference run
Problems Possible cause Remedy
SERVO-DRIVE flex for
refrigerators, freezers and
dishwashers:
If the door of the device is left
open for a relatively long time,
for example when putting away
shopping, a vacuum may be
created inside the refrigerator
or freezer after it has been
closed. This may result in it
not being possible to open the
door of the device for a few
seconds.
The refrigerator door does not
open.
Wait for the pressure to
neutralise (this may take up
to 20 sec).