Operation Manual
– 35 –
Output function list
Function
code
Abbre-
viation
Function item Remarks
0 noP No function (Standard setting)
1 TrM Thread trimming output Output of thread trimming signal
2 WiP Thread wiper output Output of thread wiper signal
3 TL Thread release output Output of thread release signal
4 FL Presser lifter output Output of presser lifting signal
5 bT Reverse feed stitching output Output of reverse feed stitching signal
6 EbT EBT cancel monitor output State of one time cancel of reverse feed stitching at end func-
tion is output.
7 SEbT Reverse feed stitching at start/end
cancel monitor output
State of cancel of reverse feed stitching at start/end is output.
8 AUbT Sewing start/end cancellation/addi-
tion monitor output
State of cancel or addition of automatic reverse feed stitching
is output.
9 SSTA Sewing machine stop state output Sewing machine stop state is output.
10 CooL Needle cooler output Output for needle cooler
11 bUZ Buzzer output It is output when the bobbin counter set value has been ex-
ceeded, an error has occurred or the bobbin thread remaining
amount is detected.
12 LSWo Revolution command output Revolution demanding command state is output.
Output function connector
Connector No. Pin No. Display No. Function Initial value of No. 12
CN22 3 o.1 Reverse feed stitching output bT
CN22 7 o.2 Thread trimming output TrM
CN22 14 o.3 Revolution request input LSWo