User's Manual
SmartAlert 8214/8205 Programming/Installation Guide 320124E Page 16
• The telephone system then detects current flowing from its source of battery,
through the SmartAlert transmitter with telephone's loop closure, and back to
the telephone system. The current flow energizes relays in the telephone
system, which connect bi-directional audio lines through Tip and Ring to the
SmartAlert transmitter with telephone.
• Once connected, the SmartAlert transmitter with telephone prompts the caller
to enter a pager number. The caller must enter this number via a true DTMF
tone type telephone. The DTMF tones must be at least 50 msec in duration
with a 50 msec pause between digits. Numbers entered via Rotary dial, or
Digital phone systems are not recognized by the SmartAlert transmitter with
telephone.
• Termination of the call can be accomplished in three different ways:
1) The calling party hangs up their telephone before the SmartAlert
transmitter with telephone times out. This terminates the call at the
telephone end, but not at the encoder’s end. The disconnect created by
the caller hanging up its phone never makes it through the connection
between the telephone system and the SmartAlert transmitter with
telephone. To overcome this loss of a disconnect signal the encoder uses
an ‘inactivity timer’ which will time out and terminate the call, in the
encoder, after a loss of audio on Tip and Ring for approximately four
seconds.
2) The SmartAlert transmitter with telephone times out before the calling part
hangs up the telephone; this terminates the call at the encoders end.
3) The calling party enters the correct string of digits described in the section
‘Paging a Single Pager Using the Telephone Interconnect’. When the last
(#) pound key is pressed the page is sent and the call is terminated.
Appendix B - Detailed Technical Specifications
SmartAlert Model 8214/8205Transmitter
Item Specification
Operating voltage 13.8 volts 1.7 amp external wall mount power supply
Power Output 0.5 - 2 watts (Factory set; default is 2W)
Modulation FSK 512 BPS
Protocol POCSAG
Antenna port 50 ohm BNC with Whip Antenna and rotating base
Mounting Horizontal for Base Mounting/ Vertical for wall mount
Data Format 7 digit extended [recommended]
Operating frequency UHF synthesized 450 MHz-470 MHz
Temperature Stability -30
o
C to +50
o
C better than 5 ppm
Size 13.3” L (338 mm) x 6.5" H (165 mm) x 2.37 "T (60 mm)
Weight 4.3 lbs. (625 g)