User's Manual
Table Of Contents
15
Connecting the Cancel or Expeditor Panel with Managers Button
1. The Cancel/Expeditor Panel must be connected to the Kitchen Controller
Panel before connecting power.
2. Connect the Cancel/Expeditor Panel to the Kitchen Controller Panel using
the 25’ (7.6m) the RJ12 Phone Cord supplied.
3. Plug the Phone Cord into the gray “REMOTE” jack of the Controller Panel
and into the gray “REMOTE” jack of the Cancel/Expeditor Panel.
4. Plug 1 end of the RJ-12 100’ (30m) Cable into the Kitchen Controller Panel
“EXPANSION” jack and the other end into the Managers Button.
• Do not use the Managers Button as a power source. Attempt to do so will
damage the Controller
• When the Button is pressed, the Controller sends a “00” message to the
Manager Pagers.
Kitchen Controller
Buttons 1-20
Cancel/Expeditor
Panel
Buttons 1-20
Managers
Button
Connecting a 20 Button System with Cancel/Expeditor Panel
All Expansion Panels
connect together
using the supplied
1’ (0.3m)Cables.