User's Manual

HME 800.925-8091 Integration Station Serial Transmitter Page 4
INTRODUCTION
Your HME Computer Controlled Paging System has the following capabilities:
PC controlled operation via RS-232 serial port. (Using a program provided by the manufacturer only.)
2-Watts effective radiated power with approximately 1-mile open field range
Operating Frequency 457.5750 MHz
Industry standard protocol covering the full range of paging functions
PC controlled automatic switching between tone/vibe only, numeric, and alphanumeric paging message
formats, including multiple tone/vibe cadences
PC controlled automatic switching between 512, 1200, and 2400 bps RF data rates
Optional unique paging transmitter IDs available for use by VARs/Distributors
Communications protocol designed to ensure reliable communications No paging receiver database
programming is required within the paging transmitter. The unique communications protocol in the HME
paging transmitter allows you to operate the transmitter with an unlimited quantity of paging receivers.
Your HME Computer Controlled Paging System allows you to use 3
rd
Party software to send paging messages to
one or more persons via pagers, and other devices that incorporate paging data receivers. You can use a wide
variety of paging receiver types with HME Paging Systems, including tone/vibe, numeric and alphanumeric pagers.
For the list of pager capcodes please refer to the capcode list on the next page.
INSTALLATION SERIAL TRANSMITTER
Unwrap all equipment. Lock the antenna into the antenna jack on the right hand corner of the
receiver unit.
Connect one end of the DB9 serial cable to the serial DB9 port on the back of the transmitter.
Connect the other end to the serial COM port of the PC where your table management software is
located.
DB9 PORT, RJ45 PORT, USB PORT ARE USE manufacturer software only.
These external ports are operating by manufacturer software only.
Plug the power supply with the large tip into a standard 110 outlet and plug it into the power supply
connector of the sending unit. The LCD display should turn ON.
Antenna
Serial Transmitter
(DB9, RJ45, USB)
Straight through Serial
Cable
or LAN cable
To COM port
DB9 PORT,
RJ45 PORT
USB PORT
Power supply