IQBASE-N INSTRUCTION MANUAL Model No. : IQBASE-N THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS : (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER�S AUTHORITY TO OPERATE THE EQUIPMENT. Thank you for purchasing our brand-new “IQ Paging System” We are confident our cutting edge products and first rate service will satisfy your needs for years to come. Please read these instructions carefully before setting up your IQ Paging System! 1. Equipment Setup 1) Keypad Sending Unit Unwrap all sending unit components. Lock the antenna into the hole in the upper right hand corner of the sending unit.
2. Placement & Mounting Instructions 1) DESKTOP You can use your transmitter with the 20 degree wedge attached or remove the wedge and lay the transmitter flat. 2) WALL MOUNT To mount your transmitter on a wall Remove the plastic bracket (included) under the transmitter unit by unlocking the 2 latches Place the plastic bracket against the wall and with the aid of a pencil, mark the position of the mounting holes.
Default Alert Type - Vibe only Duty Alert - OFF Out of Range – OFF Baud Rate – 1200 BPS Transmission Frequency - 11 kinds selectable Reception Frequency - 457.5750 MHz fixed 3. System Programming (Transmitter Version 1.01A) To enter programming mode, press the “SETUP” button and enter the password “2580” followed by “ENTER” If the password is accepted, the display will show “use * to scroll to menu options” 1) Set Current Time At the “Set Current Time” menu, set the hour then press “ENTER” key.
display. If the time is not correct, press the “CANCEL” key twice to exit the system programming menu, 3) Range Test (Factory Default: OFF) With this feature, you can determine what distance your transmitter will cover. Remove a couple of pagers from the charger base. At the range test menu, press “#” key to turn range test “ON” Press “ENTER” to start the range test. As soon as range test is activated, you’ll notice the IQ pagers flash once every 10 seconds. Walk around your property.
“33” and “44” buttons instead of OPEN, BUS, CLEAR and EST buttons and the buttons will be functioned as Predefined Messages (3) Manager Pager If “Manager Pager” is set on, 4 buttons are recognized as shortcuts of “Manager No# 1”, “Manager No#2”, “Manager No#3” and “Manager No#4” buttons instead of OPEN, BUS, CLEAR and EST buttons and the buttons will be functioned as Predefined Messages 5) Set Pager Alert (Factory Default: Vibe Only) With this feature, you have the option of changing the way your pagers ale
) Out of Range (Factory Default: OFF) With this feature, the pager will play a melody when taken out of range of the transmitter to inform the guest that they are out of range and will miss their page. The melody will only stop when they return back within range. Setting up the Out of Range “ON” At the “Out of Range” menu, “OUT OF RANGE:” is displayed and you can select ON/OFF using “#” key. Make it “ON” and then press “ENTER” key. “Are All Pagers Returned??” is displayed and then press “ENTER” key.
Note. After setting the initial EST Time, you can enter into the “EST Add Time” Auto Decrease EST Time Every time you page the pagers, the EST Time will be decreased as much as the EST incremental time. 10) SET Base ID With this feature, you can setup the Base ID of each transmitter. Setting the Base ID At the “SET Base ID” menu, “SYSTEM BASE ID:” is displayed. Input the Base Id and then press “ENTER” key. 11) GROUP CALL ID With this feature, you can setup the GROUP CALL ID.
Setting Baud Rate At the “SET BAUD RATE” menu, you can select the baud rage using “#” key. Baud Rate List (1) 512 BPS (2) 1200 BPS 14) SET FREQUENCY With this feature, you can select the frequency you want. Setting Frequency At the “SET FREQUENCY” menu, you can select the frequency using “#” key. Frequency List (1) 450.0250 MHz (2) 450.3750 MHz (3) 457.5750 MHz (4) 458.6625 MHz (5) 461.2625 MHz (6) 461.4750 MHz (7) 462.5750 MHz (8) 463.6375 MHz (9) 469.9750 MHz 4.
- If the Default Msg is ON, preset default message will be sent. - If the Default Msg is OFF, No Message will be sent. (2) “Pager #” + “ENTER” + Numeric Message + “ENTER(SEND)” - It’ll send numeric message to the pagers.
FCC ID: WDCIQBASEN This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications (including the antennas) made to this device that are not expressly approved by the manufacturer may void the user's authority to operate the equipment.