USER GUIDE Nano SPY Ref : 11816H
TABLE OF CONTENTS I. INTRODUCTION ........................................................................................................................................ 3 a) Product contents ....................................................................................................................................................... 3 b) Symbols ......................................................................................................................................................
I. INTRODUCTION The Nano SPY is a digital probe pe capable of measuring 1 or 2 physical quantities (T or TH depending on the model) and transmitting by radio to monitoring software hosted on a Web platform through a Nano Link. The Nano SPY complies with EN 12830 with temperature probes only, and is compatible with EN 13486 which defines procedures for periodic verification. a) Product contents ➢ 1 Nano SPY ➢ 1 User guide b) Symbols RECYCLING: do not dispose of in a refuse dump or waste disposal bin.
• b) A solid metal wall will not allow transmission by radio. A perforated metal wall will allow waves to pass while attenuating them. Positioning • The Nano SPY units can be placed either inside or outside the enclosures. • For installations outside the enclosure, mount the units sufficiently high on the walls to avoid interference with obstacles and foot traffic. • Insofar as is possible, place the Nano SPY LINK in a central position relative to the measurement points.
IV. USE The Nano SPY can only be used with the My Sirius software hosted on a Web platform and with a Nano SPY Link. See MySirius online help for Nano Spy configuration. a) Off state As delivered, the Nano SPY is turned off. It can neither emit nor receive signals. b) Activation 3’’ 3’’ Once activated, the le Nano SPY automatically declares itself in MySirius if it is contact with a Link.
V. BATTERY REPLACEMENT Removing the battery Open the battery cover with a suitable object (coin) to align the marks (/!\0 = Open ; 1= Closed) Remove the battery from its lodging Replacing the battery Put the new battery in place respecting the polarity . Battery detection is confirmed by the activation of the red LED for few seconds. The device can be activated after the extinction of the red LED.
NanoSPY TH Thermo-Hygro Sensor : inside unit Operating range : -30 +70°C Measurement range Accuracy, standard version Temperature Humidity at T° from 15 to 25°C : -30 +70°C et 0-100%HR : ± 0.4°C from -20 C° to +40°C / ± 0.5°C outside this range ±3% HR from 20% to 80% ±5% HR from 0 to 20% and 80% to 100% (T° from 15 to 25°C) IP rating Frequency of measurement and transmission : IP 40 Frequency of recording : adjustable from 1 min to 24h Response time Power source : ~ 5 min.
c) IP rating : IP 65 Cable length Frequency of measurement and transmission : 50 cm and 3 m Frequency of recording : adjustable from 1 min to 24h Response time : ~ 2 min.
VIII.
©JRI 10
IX. WARANTY Our material is guaranteed for one year, parts and labor, against any manufacturing defect, functional failure or abnormal wear. This guarantee covers only the replacement of parts recognized to be defective as well as the repair of the material in question returned shipping paid to our workshops, and excludes all damages and interest or incidental expenses. The starting point of the guarantee is the date of invoice of the concerned product.