Operation Manual
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
A-22
APPENDI
X
1-4 AIS Target
1
Activation
■Manual Target Activation
An AIS target is activated by either of the mehod-1 or the method–2 as follows, and then the
vector and the heading of the target are displayed.
(Method-1 : With the software button on the screen)
1. Put the arrow cursor on the ACT button at the lower left of the screen
and click the left button of the track ball.
Cursor mode ”AIS ACT" is displayed at the upper right side on the screen.
2. Put the cross cursor “+” on the target to be activated and press the track ball
section left button .
The selected AIS target is activated.
(Method-2 : With the menu operation)
1. Left-click MENU on the screen.
Main menu opens.
2. Left-click SUB1 MENU.
SUB1 menu opens.
3. Left-click AIS/ARPA.
ARPA/AIS menu opens.
4. Left-click AIS SETTING.
AIS SETTING menu opens.
5. Left-click "ON" of "2.AIS ACTIVATE".
Cursor mode ”AIS ACT" is displayed at the upper right side on the
screen.
6. Put the cross cursor “+” on the target to be activated and press the track ball section left
button .
The selected AIS target is activated.
※
1
Refer to "1.9 Definitions of AIS Target Symbols” about the activated target.
Operation
procedure