Operation Manual
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
2-10
2
C: CENTER Indicates that the EBL1 starting point is at the own ship position.
O: OFFSET Indicates that the EBL1 starting point is not at the own ship position.
In this state, the starting point may be at the cursor position or it may be fixed at an arbitrary
position on the screen. When the button is clicked, the starting point will move with the
cursor position, then when the left button is clicked the starting point will be fixed at the
cursor location.
L: After moving the L/L FIX EBL1 starting point, the starting point is fixed by the latitude and
longitude values.
If the starting point moves out of the screen, then it will be reset automatically so that the
starting point is at the own ship position.
Note: When the EBL1 starting point moves, the mode O or L is indicated by the position
selected among the EBL OFFSET ORIGIN menu.
EBL2 starting point mode
Sets whether the EBL2 starting point is placed at the center of the own ship or at an arbitrary
position on the radar screen.
Everything else is the same as that for the EBL2 starting point mode.
Speed unit setting
Sets the speed unit.
Clicking this button will open a pull-down menu. A unit can be selected from one of the
following. An alarm is activated if the selected speed unit is not connected to the radar.
Options: MANUAL, LOG (1-axis log), 2AXW (2-axis over water), 2AXG (2-axis over ground),
GPS
If the speed unit setting is “MANUAL,” then placing the cursor over the numeric section and left
clicking will allow numeric input.
SET/DRIFT
Turns on and off SET/DRIFT correction.
If CORRECTION is on for this setting, then “CORR” will be displayed next to the button. The
number displayed next to “CORR” at this time will be valid. Also, correction can only be set
when the speed unit is in the MANUAL or LOG (1-axis log) modes.
SET setting
Placing the cursor over the numeric section and left clicking will allow numeric input. This
setting is only valid if CORRECTION is ON.
DRIFT setting
Placing the cursor over the numeric section and left clicking will allow numeric input. This
setting is only valid if CORRECTION is ON.
Date display mode
Sets the date mode to be displayed on the screen.
: Turns off the time display.
: Global time display (UCT).
: Local time display (LOCAL).
ARPA, PAST POSN vector mode setting
These set the vector display mode.
T: True vector
R: Relative vector
These settings work concurrently.