Operation Manual

A-13
APPENDIX
(2) Setting SW12 (Radar connection setting)
1 234
ON
OFF
5768
Radar connection setting
ON No. 1 display unit connection
1
OFF No. 1 display unit non-connection
2 ON No. 1 scanner unit connection
OFF No. 1 scanner unit non-connection
ON No. 2 display unit connection 3
OFF No. 2 display unit non-connection
ON No. 2 scanner unit connection 4
OFF No. 2 scanner unit non-connection
ON No. 3 display unit connection 5
OFF No. 3 display unit non-connection
ON No. 3 scanner unit connection 6
OFF No. 3 scanner unit non-connection
ON No. 4 display unit connection 7
OFF No. 4 display unit non-connection
ON No. 4 scanner unit connection 8
OFF No. 4 scanner unit non-connection
(3) SW13 (Not used)
1 234
ON
OFF
1, 2, 3, 4 Not used
Note: Set the DIP switches of the ISW circuit in accordance with the INSTALLATION
MANUAL, and ensure safety when and before setting the DIP switches.