Operation Manual
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
8-32
8
z The liquid-crystal monitor is easily damaged, even by a slight shock. When
handling this monitor for replacement, be extra careful so as not to hit a hard
object against the monitor. In addition, do not place the monitor on a hard
object.
Replacement of the Liquid-Crystal Monitor・・・・・・・・・・・・・・・・
1 JMA-9933-SA, JMA-9923-7XA/9XA (Display unit: NCD-4263)
(1) Four screws of the front of a processing part are loosened.
(2) The cable connected from the liquid crystal (LCD) part is removed. (Three)
The band which is fixing the cable is removed.
A cable is drawn out upwards.
(3) Four bolts which have stopped the liquid crystal display part to the case are
removed..
(4) A display part is removed.
(5) Four screws of a liquid crystal top and six screws (rotation part) stopped from the
lower side are removed. (It becomes only the display part of liquid crystal.)
(6) A reverse procedure performs attachment of a new liquid crystal display monitor.
Attention