Operation Manual
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
2-9
2
Heading line off setting
Has the same function as the [HL OFF] key. While this switch is clicked, the heading lines (HL)
display will be turned off.
CPA RING indicator selection
Turn on and off the CPA RING display.
When the vector mode is TRUE, the CPA RING cannot be turned on.
MAP SHIFT
This is used to mode maps made by users.
DEPTH
This displays the depth received from external devices.
The □ button can be used to turn on and off the depth graph display.
DAY/NIGHT setting
This button selects the day or night mode. The mode changes each time this button is clicked.
There are four settings: DAY1→ DAY2 → NIGHT1 → NIGHT2.
PANEL/BRILL VIDEO/BRILL ARPA setting
The modes PANEL, VIDEO, and ARPA which adjust luminosity are switched.
The mode changes each time this button is clicked.
There are three settings: PANEL→VIDEO→ARPA.
Brilliance adjustment
Each time this switch is clicked, it will go to the next of four (BRILL VIDEO) or five (PANEL,
BRILL ARPA) brilliance settings.
Process setting function (FUNC) selection
Sets the process setting mode. OFF, FUNC1, FUNC2, FUNC3, FUNC4, or FUNC5 can be
selected.
, , , : EBL and VRM settings
The EBL1, EBL2, VRM1, and VRM2 switches are used to acquire operation rights.
They function in the same way as the EBL1 and 2 and VRM1 and 2 switches on the control
panel.
The numeric indicator switches are used to turn on and off the various EBLs and VRMs.
When a numeric indicator displays “OFF,” that means the corresponding indicator in the PPI is
off.
The switches on the control panel are used to move the EBLs and VRMs.
EBL1 T051.0 °
EBL2 T135.0 °
● VRM1 0.30 nm
○ VRM2 0.60 nm
EBL1 starting point mode
Sets whether the EBL1 starting point is placed at the center of the own ship or at an arbitrary
position on the radar screen. This has the same function as depressing the EBL1 switch on the
control panel for a long period.
26
27
28
29
30
32
This is used to turn ON and OFF either EBL or VRM operation, and turn ON and OFF the display.
The function that is valid is indicated by the inverted display.
EBL and VRM intersection identification marks
When ON: The numeric display is off.
When OFF: The numeric display is on.
33
3534 36 37
38
31