Operation Manual

8-42
Procedures
z Do not change the adjusted level carelessly. If the adjustment is improper, the
target signals on the short ranges may be cleared.
200P/90×
OFF ON
400P/180×
ON OFF
/NM
800P/360×
OFF OFF
S2 Setting Table
1 2 3 4
LOG ALM
GYRO
SIMULATOR
LOG
SIMULATOR
N/A
5 6 7 8
S2
GYRO ALM
ON=5S,OFF=0.5S
N/A N/A N/A
Main Bang Suppression Adjustment・・・・・・・・・・・・・・・・・・・・・・・・
The adjustment is intended for suppressing the main bang that is an echo signal from the
microwave circuit such as waveguide appearing as a circular echo at the radar video
center. It is the optimum level in which the main bang suppression is adjusted so that the
main bang remains weak on the video.
1 Set the radar range scale to the minimum 0.125 NM, set
PROCESS, TGT ENH and FUNCTION to OFF, and set the
system to the Transmit mode.
2 Adjust the operation controls as
follows:
[GAIN] control: Maximum
[SEA] control: Center (MANUAL)
[RAIN] control: Minimum (MANUAL)
3 Click MENU on the screen.
Or press OPTION2 key.
The MAIN Menu will appear.
4 Click CODE INPUT .
The CODE INPUT Menu will appear.
Attention
ADJUST
0.
EXIT
00-255
MBS
1.MBS LEVEL
2.MBS AREA
0-255
0