Operation Manual
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
A-41
APPENDIX
3.Installation of AIS Information Display Kit
Note:
Following connection and setup are not required if the AIS interface was built in the factory before
shipping.
3-1. Composition of AIS Information Display Kit
The AIS kit for JMA-9900 consists of .
-AIS I/F TYPE : AIS I/F PCB, Base attachment
-7ZCRD0967 : Power and Communication cable
3-2. AIS I/F Connection
(1) Attach the AIS I/F in the indicator. Refer to AIS UNIT INSTALLATION MANUAL.
(2) Connect the communication cable as shown in the following figure.
(3) P
o
w
e
r
c
a
b
l
e
c
o
n
n
e
c
tion
Connect P16 of attached cable to J16 of the terminal board.
Connect P1 of attached cable to J1 of AIS I/F board.
When ISW is equipped, exchange the existing power cable with the 7ZCRD0967 power cable
in this kit.
AIS I/F Board
TB 4601
Covering is skinned and
itconnects with a terminal
board.
To J500
To J1
①
②
③
P500
P1
COMCD
COMRX
COMTX
COMTR
COMSG
COMDSR
COMRTS
COMRI
J16
P16
Power and Communication
cable 7ZCRD0967
Red
Green
Blak
JMA-9900 Terminal Board