Operation Manual
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
11-12
11
11.12 ARPA ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
(1) Acquisition
・Acquisition Mode :Auto/Manual Acquisition(Targets are acquired
within guard zone in the automatic acquisition
mode)
・Manual Cancellation of
Unwanted Target :Each One Target or All Target at once
(2) Tracking
・Number of Targets :50 Targets (Auto Tracking)
・Acquisition and
Tracking Range :32 NM
(3) Presentation
・Display Modes :TM (True Motion) / RM (Relative Motion)
・Bearing Modes :North-up / Head-up / Course-up
・Vector Modes :True/Relative Display
Vector Length:Adjustable from 1 to 60 min
・Past Position Display :True / Relative Display
Number of Dots:6 points
Display Time 30sec, 1 min, 2 min, 4 min
・Time to Display Vector :Within 1 min
・Time to Stabilize Vector :Within 3 min
(4) Alarm
・Guard Zone :2
・Setting Ranges :Guard Zone 1 (0.5 - 32 NM),
Guard Zone 2 (0.5 - 32 NM)
・Alarm Indication : mark on LCD with Visible / Audible alarm
(5) Safe Limits (CPA/TCPA)
・Setting Condition :CPA LIMIT (0.1 - 9.9 NM)
TCPA LIMIT (1 - 99 min)
・Alarm Condition :
Safe
Target
・CPA>CPA LIMIT
・ 0>TCPA
・ TCPA>TCPA LIMIT
Danger
Target
・ CPACPA LIMIT,
0TCPATCPA LIMIT
・Alarm Display :
Status LCD Symbol Alarm Buzzer
Safe Ship
〇
OFF OFF
Danger Ship
CPA/TCPA
ON
・Lost Target : mark on LCD
Visible / Audible Alarms