Operation Manual

8-38
Procedures
z Do not change the set value carelessly.
The vector constant shall be set to 4 normally. If the vector constant value is
higher, a target’s vector will be better followed up when the target and own ship
change their course or speed, but the vector accuracy will be lower on the
Vector Constant・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
1 Click MENU on the screen. Or press OPTION2 key.
The MAIN Menu will appear.
2 Click CODE INPUT.
The CODE INPUT Menu will appear.
3 Click 0 , then END .
The ADJUST Menu will appear.
4 Click ARPA/AIS .
The ARPA/AIS Menu will appear.
5 Click the 1. VECT CONSTedit box.
1.VECT CONST will be selected.
6 Input the new value by pressing the 0
to 8 number buttons or by using the + or - buttons, then
press END to input.
1 Click EXIT .
The ADJUST Menu will be closed.
2 Click EXIT .
The CODE INPUT Menu will be closed.
3 Click EXIT .
The MAIN Menu will be closed.
Attention
EXIT
ARPA/AIS
ADJUST
0.
EXIT
3.LIMIT RING
VIDEO LEVEL
1-8
1.VECT CONST
4
OFF ON