Operation Manual
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
5-26
5
Using the TRIAL Function・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
1 Press the MENU or OPTION2 key on the screen.
The ARPA menu will be opened.
2 Click SUB1 MENU , then ARPA/AIS and TRIAL .
The ARPA TRIAL menu will be opened.
3 Left-click “ON” under “1.TRIAL”.
“1.TRIAL” will be turned “ON” and the character “T” will blink below the own ship
display in the radar screen, indicating that the system is conducting a trial.
4 Make the settings with the course [EBL] control and speed
[VRM] control.
5 The plot data symbols are “△” for dangerous targets and “○”
for safe targets.
1 Select OFF under TRIAL in the ARPA TRIAL menu.
“OFF” will be set for “TRIAL” and the system will return to the normal display.
1 Click EXIT .
The ARPA TRIAL menu will be closed.
2 Click EXIT .
The ARPA menu will be closed.
Procedures
Cancellation
Exit