Users Manual
Settings & Registrations
5-14
5.5.6 Setting the inactivity timeout timer
If a call event is left without operation for a while, the call event is automatically ended after the
setting time is elapsed. The inactivity timeout timer can be set as follows.
■ Procedure ■
1
1
1
.
.
.
Touch the [INACTV T/O] button to display the screen
as shown at right.
2
2
2
.
.
.
Change the timer settings as appropriate.
This menu includes the following settings. Furthermore,
set to OFF if making the inactivity timeout timer invalid
ACK DIST: The acknowledged distress alert events
(00 (OFF) - 60 minutes)
RCV DIST: The distress events of other ships
(00 (OFF) - 60 minutes)
NON DIST: Routine, safety and urgency events
(00 (OFF) - 60 minutes)
OTHER COMM: Communications without using DSC.
(10 - 600 seconds, No off-setting)
3
3
3
.
.
.
After the settings is complete, touch the [✓] button to save them.