Joyce/Dayton Corp. Operation and Maintenance Manual for Multipurpose Actuators 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator The recommendations in this manual for installation, operation and maintenance must be followed to ensure safe use. All persons responsible for the installation and use of Joyce/Dayton Multipurpose Actuators must be familiar with the contents of this manual.
Table of Contents Section I – General Information 1-1 Contact Joyce/Dayton ......................................................................................................... 3 1-2 Purpose and Scope ............................................................................................................. 3 1-3 Receipt of Product ............................................................................................................... 3 1-4 Warranty ............................................
Section I General Information 1-1 Contact Joyce/Dayton Corp. Joyce/Dayton Corp. P.O. Box 1630 Dayton, OH 45401 (800) 523-5204 (US and Canada) (937) 294-6261 (937) 297-7173 Fax Email: sales@joycedayton.com Website: www.joycedayton.com 1-2 Purpose and Scope This manual provides installation, operation and maintenance instruction for standard Joyce/Dayton Multipurpose Actuators. For special units not covered, please contact Joyce/Dayton Corp.
5. Multipurpose actuators can be mounted and operated in any orientation, but the load must be axial to the actuator. No side load is permitted. Refer to Section 1-9 for installation guidelines. 6. Be certain the rating of the actuator meets or exceeds the load. 7. The actuator must be mounted on a rigid structure sufficient to support the maximum possible load. An under-designed structure could lead to premature wear or failure. 8.
4. To set the upper limit switch position, secure the inner tube from rotating by either gripping it by hand or slide a screwdriver through the clevis hole and lay the actuator down flat on a suitable work surface. 5. Electrically operate the actuator until the desired extend position is reached. If the actuator stops on its own before reaching the desired position the retract position may have been set too high and the physical travel limitations of the actuator have been exceeded.
1-8 Wiring Instructions for Motor and Potentiometer 12 VDC Motor - MA0513 The actuator will extend when the red wire connects to the positive lead and the black wire connects to the negative lead. It will retract when the black wire connects to the positive lead the red wire connects to the negative lead. See Figure 3 below.
Potentiometer (for 12 VDC and 120 VAC Actuators) The potentiometer has a 0 -10 K Ohm resistance range. The actual resistance value is a variable that is based on the stroke length. It is measured between the blue and white wires. Values have a +/-0.3 K Ohm tolerance. Refer to the Figure 6 for the potentiometer schematic. Ohm value between blue & white wire Stroke (mm) 100 Approximate Resistance (Ohm) 0.3 – 8.0 K 150 or 153 0.3 – 8.5 K 200 0.3 – 9.1 K 300 or 305 0.3 – 8.6 K 457 0.3 – 9.
Section II Multipurpose Actuator Drawings 2-1 (12 VDC) MA0513 Drawing and Charts Drawing dimensions shown in millimeters Part Number (VDC) MA0513B1110 MA0513B1115 MA0513B1125 MA0513B1130 Capacity N (lb) Stroke Mm (in) Travel speed mm/sec (in/min) Retracted (A) mm (in) 500 (112) 500 (112) 500 (112) 500 (112) 100 (3.9) 150 (5.9) 250 (9.8) 300 (11.8) 13 (31) 13 (31) 13 (31) 13 (31) 246 (9.7) 297 (11.7) 399 (15.7) 450 (17.
2-2 (12 VDC) MA1527 & MA3507 Drawing and Charts Drawing dimensions shown in millimeters Part Number (VDC) MA1527B1115 MA1527B1130 MA1527B1145 MA3507B1115 MA3507B1130 MA3507B1145 Capacity N (lb) Stroke mm (in) Travel speed mm/sec (in/min) Retracted (A) Mm (in) 1500 (337) 1500 (337) 1500 (337) 153 (6.0) 305 (12.0) 457 (18.0) 27 (64) 27 (64) 27 (64) 410 (16.1) 613 (24.1) 765 (30.1) 3500 (787) 3500 (787) 3500 (787) 153 (6.0) 305 (12.0) 457 (18.0) 7 (17) 7 (17) 7 (17) 410 (16.1) 613 (24.1) 765 (30.
2-3 (12 VDC) MA2547, MA3527, MA4514, MA7007 Drawing and Charts Drawing dimensions shown in millimeters Part Number (VDC) MA2547B1115 MA2547B1130 MA2547B1145 MA3527B1115 MA3527B1130 MA3527B1145 MA4514B1115 MA4514B1130 MA4514B1145 MA7007B1115 MA7007B1130 MA7007B1145 Capacity N (lb) Stroke (S) mm (in) Travel speed mm/sec (in/min) Retracted (A) mm (in) 2500 (562) 2500 (562) 2500 (562) 3500 (787) 3500 (787) 3500 (787) 4500 (1012) 4500 (1012) 4500 (1012) 7000 (1574) 7000 (1574) 7000 (1574) 153 (6.
2-4 (120 VAC) MA1527 & MA3507 Drawing and Charts Drawing dimensions shown in millimeters Part Number (VAC) MA1527B8115 MA1527B8130 MA1527B8145 MA3507B8115 MA3507B8130 MA3507B8145 Capacity N (lb) Stroke mm (in) Travel speed mm/sec (in/min) Retracted (A) Mm (in) 1500 (337) 1500 (337) 1500 (337) 153 (6.0) 305 (12.0) 457 (18.0) 23 (54) 23 (54) 23 (54) 410 (16.1) 613 (24.1) 765 (30.1) 3500 (787) 3500 (787) 3500 (787) 153 (6.0) 305 (12.0) 457 (18.0) 6 (14) 6 (14) 6 (14) 410 (16.1) 613 (24.
2-6 (120 VAC) MA2547, MA3527, MA4514, MA7007 Drawing and Charts Drawing dimensions shown in millimeters Part Number (VAC) MA2547B8115 MA2547B8130 MA2547B8145 MA3527B8115 MA3527B8130 MA3527B8145 MA4514B8115 MA4514B8130 MA4514B8145 MA7007B8115 MA7007B8130 MA7007B8145 Capacity N (lb) Stroke (S) mm (in) Travel speed mm/sec (in/min) Retracted (A) mm (in) 2500 (562) 2500 (562) 2500 (562) 3500 (787) 3500 (787) 3500 (787) 4500 (1012) 4500 (1012) 4500 (1012) 7000 (1574) 7000 (1574) 7000 (1574) 153 (6.
Section III Order information 3-1 Part Number Description 3-2 Serial Number The serial number is etched on the front of each actuator, just below the Joyce Logo. Use the serial number to positively identify the actuator when reordering or when communicating with Joyce/Dayton. Joyce/Dayton Corporation P.O. Box 1630 Dayton, Ohio 45401 Phone (800) 523-5204 (U.S. & Canada); (937) 294-6261 Fax (937) 297-7173 www.joycedayton.com E-mail: sales.jacks@joycedayton.
Manual available at www.joycedayton.