ADJUSTMENT:
Refer to figure 1. The electrical switch units “G”, “H”, ”L”, and “M” are shown with contact
positions assumed when the cams are not actuating the switch units.
When the cam rotates and actuates the “B” (closed) contact opens and the ‘A” (open) contact
closes. Each electrical switch unit has (1) one independent adjustable cam.
To Adjust “G” Switch
1. Loosen Yellow set screw.
2. Turn screw “C” until cam trips “G”
3. Retighten Yellow set screw.
To Adjust “H” Switch
1. Loosen Green set screw.
2. Turn screw “D” until cam trips “H”
3. Retighten Green set screw.
To Adjust “L” Switch
1. Loosen Blue set screw.
2. Turn screw “J” until cam trips “L”
3. Retighten Blue set screw.
To Adjust “M” Switch
1. Loosen Red set screw.
2. Turn screw “K” until cam trips “M”
3. Retighten Red set screw.
A
B
A
B
A
B
A
B