Configuration of data group
Data groupM0
The M0 data group is a special case. It is the standard data group. Each
time an alternative data group is selected or changes are made to the
existing settings, M0 is immediately overwritten with the newly selected
data. M0 is therefore a real-time duplicate of the currently selected data
group. It is also the data set that is stored when the power is turned o
and recalled the next time the power is turned on. This is done auto-
matically and transparently without user input.
Selecting the processing data group
Navigate to the option M-PRE to edit a data group. Rotate the rotary
switch to choose the number of the data group which should be edited.
Aer finishing the settings hold down SET until the number of the data
group is shown on the right side of the screen. By pressing SET again,
you leave the data group settings.
Activation / deactivation
Navigate to the option M-PRE and press the rotary switch. Aer that
rotate the switch to choose the data group by its number which you
want to see and edit. Press it again to change the status of the option
M-PRE.
By activating this option, the output stays the same by selecting a data
group.
By deactivating this option, the output is automatically switched o by
selecting a data group.
Hold down SET until the number of the data group is shown on the right
side of the screen. The data value will be saved in the data group of the
shown. Press SET again to return to the menu. To leave this menu press
SET.
Data group quick selection
Key combination to choose M1 / M2
Hold down V/↑ or A/↓ for longer than 3 seconds to select the data
group M1 or M2 as a quick selection. The number of the according data
group is shown on the right side of the screen. The data group M1 and
M2 are perfect for frequently used settings because of their quick
selection function.
Selecting an arbitrary data group
Hold down SET for more than 3 seconds to show M0 on the right side of
the screen. Through rotating the rotary switch is it possible to choose
the requested data group (M0 - M9). To activate the chosen data group,
press SET.