Instructions

Conguration of the data groups
Data group M0
The data group M0 is a special case. It is the standard data group. Every
time an alternative data group is chosen or changes at the current settings
are made, the M0 is immediately overwritten by the new data. M0 is
therefore a realtime duplicate of the current chosen data group and the
values. It is also the set of data which is saved by switching o and will
be invoked by starting the device again. This happens automatically and
transparently without any input of the user.
Selection of the processing data group
Navigate to option M-PRE to edit a data group. Rotate the rotary switch
to choose the number of the data group which should be edited. Aer
nishing the settings hold down SET until the number of the data group is
shown on the right side of the screen. By pressing again SET, you leave the
data group settings.
Activation / deactivation
Navigate to option M-PRE and press the rotary switch. Aer that rotate that
switch to choose the data group by its number which should be edited.
Press it again to change the option M-PRE.
By activating this option, the output stays the same by invoking a data
group.
By deactivating this option, the output is automatically switched o by
invoking a data group.
Hold down SET until the number of the data group is shown on the right
side of the screen. The data value will be saved under the number of the
data group. Press again SET to return to the menu. To leave this menu press
SET.
Datagroup quick selection
Key combination by choosing M1 / M2
Hold down V/or A/for longer than 3 seconds to select the data group
M1 or M2 quickly. The number in accordance with the data group is shown
on the right side of the screen. The data group M1 and M2 are perfect for
frequently used settings because of their quick selection function.
Selection of an arbitrary data group
Hold down SET for more than 3 seconds to show M0 on the right side of
the screen. Through rotating the rotary switch is it possible to choose the
desired data group (M0 - M9). To activate the chosen data group, press SET.